TF Tube Furnace Range

Carbolite’s versatile new TF tube furnace range incorporates high-quality heating elements and innovative thermal insulation design to achieve first class performance while maintaining both reduced case temperatures and power consumption.

The TF range has been designed with flexibility in mind. Slide-in accessory work tubes and the use of tube adapters allow a single furnace to accommodate a variety of tube diameters, whilst the work tubes themselves can easily be exchanged to meet the different physical or chemical requirements of a process.

Optional work tube packages enable users to equip the TF for operation under vacuum or modified atmosphere.

Overview

  • Max temp: 1100, 1200, 1600°C
  • Furnace Ø: 32, 60, 100, 125 mm
  • Heated length(s): 150, 180, 300, 450, 600, 800, 1000, 1200 mm
  • Number of heated zones: 1 zone or 3 zones
  • Orientation: All models available orientated either horizontally or vertically

TF Tube Furnace Range Leading Heat Technology

Carbolite's new tube furnace range is at the pinnacle of furnace design. The culmination of over 80 years of experience in thermal engineering; combining the latest technological developments with solid construction, high-quality components and a sleek, modern aesthetic.

High quality heating elements

  • Excellent temperature uniformity
  • Fast heat-up and cool-down rates
  • Unsurpassed temperature uniformity along the entire heated length

High quality thermal insulation

  • Low energy consumption
  • Low external case temperature
  • Designed for longevity
TF & TS Tube Furnace Range - Introduction Video

Product Video: TF Tube Furnace Range

TF Tube Furnace Range Excellent temperature uniformity: Hot stuff!

Carbolite’s tube furnace range boasts a variety of technical features to maximise the heated length of the furnace, ensuring that as much of the work tube as possible is heated to the setpoint temperature. These include heating elements evenly distributed around the work tube and low thermal mass insulation.

To achieve the longest possible heated length, our 3-zone models feature increased power boosting at the ends of the furnace, ensuring the best possible temperature uniformity throughout the working volume.

Combining your furnace with work tube packages that include thermal insulation plugs or radiation shields helps prevent thermal losses from the ends of the work tube. Carbolite are hard to beat, when it comes to the uniform distribution of heat!

TF3 12/125/600

Measured under controlled laboratory conditions. Results may vary depending on process-specific variables, e.g. gas flow rates, vacuum levels, and sample material, size/density.

TF3 12/60/600

Measured under controlled laboratory conditions. Results may vary depending on process-specific variables, e.g. gas flow rates, vacuum levels, and sample material, size/density.

TF3 12/125/600

Measured under controlled laboratory conditions. Results may vary depending on process-specific variables, e.g. gas flow rates, vacuum levels, and sample material, size/density.

TF3 12/60/600

Measured under controlled laboratory conditions. Results may vary depending on process-specific variables, e.g. gas flow rates, vacuum levels, and sample material, size/density.

TF1 11/32/150

Measured under controlled laboratory conditions. Results may vary depending on process-specific variables, e.g. gas flow rates, vacuum levels, and sample material, size/density.

TF Tube Furnace Range Temperature control & communications

TF tube furnaces are equipped with ethernet communications and a programmable controller with 24 segments as standard:

  • Single zone furnaces fitted with Carbolite EPC3016P1 controller
  • Three zone furnaces fitted with Carbolite AriesPlus touch-screen controller

Options

  • Over-temperature protection (recommended to protect valuable contents and for unattended operation) (1600°C models are equipped with this option as standard)
  • A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS485 or Ethernet communications. More Information

Temperature controller AriesPlus

TF Tube Furnace Range Rapid heating rates

Carbolite tube furnaces are equipped with high-quality heating elements designed to achieve fast heat-up rates.

Optimise your lab time by speeding up your heat treatment processes!

Precise temperature measurements are carried out in the Carbolite testing laboratory and available for all models.

Maximum heating rates of exemplary tube furnace models

measured with a quartz work tube and insulation plugs fitted

Cooling rates of exemplary tube furnace models

measured with a quartz work tube and insulation plugs fitted

TF Tube Furnace Range Mounting configurations

This range of tube furnaces is supplied in one of two standard mounting configurations.

  1. For heated lengths up to 600 mm the furnace body is mounted on top of the control box. The furnace body can easily be detached and separated for remote operation.
  2. For heated lengths of 800 mm and above the furnace body and control box are always separate.
Both configurations include a 2 metre cable (furnaces with 125 mm Ø incl. plug and socket) between the furnace body and control box. This flexible arrangement allows for easy conversion to optional mounting arrangements e.g. attaching to a vertical stand, a mounting bracket or inside a fume cupboard.

Furnace body on top of control box

Configuration for heated lengths up to 600 mm

Detachable furnace body

Easy conversion to optional mounting arrangements

Furnace body and separate control box

Configuration for heated lengths of 800 mm and above

Option: Vertical stand

Vertical mounting stand for the furnace body

Option: Mounting bracket

Used to mount the furnace body to customer equipment

Option: 4 m cable extension

4 m long extension results in a total of 6 m between furnace body and control box (125 mm Ø models include plug and socket)

High-quality thermal insulation Low energy consumption

Carbolite's new tube furnaces are very energy-efficient. Their high-quality thermal insulation is designed for longevity, low case temperature and most of all outstandingly low energy consumption.

Using a Carbolite tube furnace reduces your energy cost as well as the carbon footprint.

Up to 50% less energy required! Comparison with equivalent competitor product

Energy consumption for exemplary Carbolite TF1 12/60/600 model (red) and equivalent competitor product (yellow); measured at each temperature after 2 hours soak.

TF Tube Furnace Range Modified atmosphere & vacuum equipment

Carbolite tube furnaces may be equipped with many different options to accommodate modified atmosphere and/or vacuum applications.

Options

  • A range of additional work tubes, end seals and complete work tube packages
  • Vacuum packages with a choice of rotary vane pumps or turbomolecular pumps
  • Inert gas package modules allow for the use of up to 3 non-reactive gases (available with either manual or automatic control)
  • Laboratory Gas Safety System for safe use with hydrogen above 750 °C
Modified Atmosphere and Vacuum Options for Carbolite Gero Tube Furnaces

Introduction to modified atmosphere and vacuum options for tube furnaces

TF Tube Furnace Range That's cool! Low case temperature

Carbolite tube furnaces are designed with user safety in mind.

The robust construction and high-quality thermal insulation ensure that external case temperatures are much lower than other models.

Not only does this help mitigate the risk of injury to the operator, the reduction in the amount of heat escaping the furnace ensures a comfortable working environment, and also means that less energy is wasted during use.  When the heat is on, Carbolite can help you keep a cool head!

 

TF Tube Furnace Range Accessories

Large selection of work tubes

Wide choice of tube diameters, lengths & materials

Insulation plugs & radiation shields

Prevent heat loss & improve temperature uniformity

TF Tube Furnace Range Technical Data

Number of heated zones Max temp (°C) Furnace Ø Heated length (mm) Heat-up time (mins) Tube length for use in air (mm) Tube length for use with modified atmosphere (mm) Dimensions: External H x W x D (mm) Uniform length ±5°C (mm) Max power (W) Weight (kg)
TF1 11/32/150 1 1100 32 150 27 300 500 455 x 335 x 470 58 575 16
TF1 12/60/300 1 1200 60 300 35 580 750 575 x 495 x 480 177 1500 37
TF1 12/60/450 1 1200 60 450 45 730 900 575 x 645 x 480 318 2000 49
TF1 12/60/600 1 1200 60 600 45 880 1050 575 x 795 x 480 474 2500 56
TF1 12/125/400 1 1200 125 400 88 750 1000 665 x 665 x 480 284 1860 71
TF1 12/125/600 1 1200 125 600 90 950 1200 665 x 865 x 575 456 2510 89
TF1 12/125/800 1 1200 125 800 85 1150 1400 445 x 1065 x 575* 635 3160 102
TF1 12/125/1000 1 1200 125 1000 80 1350 1600 445 x 1265 x 575* 847 3810 120
TF1 12/125/1200 1 1200 125 1200 82 1550 1800 445 x 1465 x 575* 969 4460 134
TF1 16/60/180 1 1600 60 180 -- 680 900 665 x 595 x 585 100 2500 43
TF1 16/60/300 1 1600 60 300 -- 800 1020 665 x 715 x 585 175 4000 51
TF1 16/100/450 1 1600 100 450 -- 1030 1250 790 x 940 x 705 320 6000 90
TF1 16/100/600 1 1600 100 600 -- 1180 1400 790 x 1090 x 705 425 7000 100
TF3 12/60/450 3 1200 60 450 55 730 900 575 x 645 x 480 340 2000 49
TF3 12/60/600 3 1200 60 600 55 880 1050 575 x 795 x 480 501 2500 56
TF3 12/125/600 3 1200 125 600 90 950 1200 665 x 865 x 575* 507 2510 89
TF3 12/125/800 3 1200 125 800 85 1150 1400 445 x 1065 x 575* 715 3160 102
TF3 12/125/1000 3 1200 125 1000 80 1350 1600 445 x 1265 x 575* 855 3810 120
TF3 12/125/1200 3 1200 125 1200 82 1550 1800 445 x 1465 x 575* 1055 4460 134
TF3 16/100/450 3 1600 100 450 -- 1030 1250 790 x 940 x 705 375 6800 90
TF3 16/100/600 3 1600 100 600 -- 1180 1400 790 x 1090 x 705 460 8000 100

Model names explained

TF1 11/32/150 Number of heated zones: 1 zone or 3 zones
TF1 11/32/150 Max temp: 1100, 1200, 1600°C
TF1 11/32/150 Furnace Ø: 32, 60, 100, 125 mm
TF1 11/32/150 Heated length(s): 150, 180, 300, 450, 600, ... mm

Please note

  • Heat up time is measured to 100 °C below max, using an empty quartz tube & insulation plugs
  • Heat up rate when using an optional ceramic work tube must be limited to 5 °C/min
  • Holding power is measured at continuous operating temperature
  • Uniform temperature lengths are measured with insulation plugs fitted at 100°C below maximum temperature
  • Maximum continuous operating temperature is 100 °C below maximum temperature
  • 1100°C and 1200°C models are equipped with thermocouple type N, 1600°C models with type R
  • * Furnace with separate control box

TF Tube Furnace Range Downloads