LHTM 100-200/16-1G
| Insulation material |
Molybdenum |
| Volum (l) |
1.5 |
| Tmax vacuum (°C) |
1600 |
| Tmax atmospheric pressure (°C) |
1600 |
[citiți mai mult]
[citiți mai puțin]
| Dimensiuni: Externe H x W x D (mm) |
1800 x 1900 x 1000 |
| Transport weight (kg) |
800 |
| Usable space |
|
| Ø x H, usable space without retort (mm) |
100 x 200 |
| Ø x H, usable space with retort (mm) |
90 x 200 |
| Thermal values |
|
| -Delta-T, between 500°C and 2200°C (K) according to DIN 17052 |
± 10 |
| Max. heat-up rate (K/min) |
10 |
| Cooling time (h) |
2.5 |
| Connecting values |
|
| Putere (kW) |
22 |
| Voltage (V) |
400 (3P) |
| Current (A) |
3 x 55 |
| Series fuse (A) |
3 x 63 |
| Vacuum (option) |
|
| Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
| Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
| Cooling water required |
|
| Flow (l/min) |
30 |
| Max. inlet temperature (°C) |
23 |
| Gas supply |
|
| Nitrogen or Argon flow, others on request (l/h) |
50-500 |
| Controller |
|
| Manual operation |
TP1200 touch panel |
| Automatic operation |
TP1900 touch panel, Siemens S7-1500 PLC |
LHTM 200-300/16-1G
| Insulation material |
Molybdenum |
| Volum (l) |
10 |
| Tmax vacuum (°C) |
1600 |
| Tmax atmospheric pressure (°C) |
1600 |
[citiți mai mult]
[citiți mai puțin]
| Dimensiuni: Externe H x W x D (mm) |
1800 x 1900 x 1000 |
| Transport weight (kg) |
950 |
| Usable space |
|
| Ø x H, usable space without retort (mm) |
200 x 300 |
| Ø x H, usable space with retort (mm) |
180 x 300 |
| Thermal values |
|
| -Delta-T, between 500°C and 2200°C (K) according to DIN 17052 |
± 10 |
| Max. heat-up rate (K/min) |
10 |
| Cooling time (h) |
4 |
| Connecting values |
|
| Putere (kW) |
45 |
| Voltage (V) |
400 (3P) |
| Current (A) |
3 x 65 |
| Series fuse (A) |
3 x 80 |
| Vacuum (option) |
|
| Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
| Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
| Cooling water required |
|
| Flow (l/min) |
50 |
| Max. inlet temperature (°C) |
23 |
| Gas supply |
|
| Nitrogen or Argon flow, others on request (l/h) |
50-500 |
| Controller |
|
| Manual operation |
TP1200 touch panel |
| Automatic operation |
TP1900 touch panel, Siemens S7-1500 PLC |
LHTW 100-200/22-1G
| Insulation material |
Tungsten |
| Volum (l) |
1.5 |
| Tmax vacuum (°C) |
2200 |
| Tmax atmospheric pressure (°C) |
2200 |
[citiți mai mult]
[citiți mai puțin]
| Dimensiuni: Externe H x W x D (mm) |
1800 x 1900 x 1000 |
| Transport weight (kg) |
850 |
| Usable space |
|
| Ø x H, usable space without retort (mm) |
100 x 200 |
| Ø x H, usable space with retort (mm) |
90 x 200 |
| Thermal values |
|
| -Delta-T, between 500°C and 2200°C (K) according to DIN 17052 |
± 10 |
| Max. heat-up rate (K/min) |
10 |
| Cooling time (h) |
3 |
| Connecting values |
|
| Putere (kW) |
45 |
| Voltage (V) |
400 (3P) |
| Current (A) |
3 x 112.5 |
| Series fuse (A) |
3 x 160 |
| Vacuum (option) |
|
| Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
| Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
| Cooling water required |
|
| Flow (l/min) |
50 |
| Max. inlet temperature (°C) |
23 |
| Gas supply |
|
| Nitrogen or Argon flow, others on request (l/h) |
50-500 |
| Controller |
|
| Manual operation |
TP1200 touch panel |
| Automatic operation |
TP1900 touch panel, Siemens S7-1500 PLC |
LHTW 200-300/22-1G
| Insulation material |
Tungsten |
| Volum (l) |
10 |
| Tmax vacuum (°C) |
2200 |
| Tmax atmospheric pressure (°C) |
2200 |
[citiți mai mult]
[citiți mai puțin]
| Dimensiuni: Externe H x W x D (mm) |
1800 x 1900 x 1000 |
| Transport weight (kg) |
1000 |
| Usable space |
|
| Ø x H, usable space without retort (mm) |
200 x 300 |
| Ø x H, usable space with retort (mm) |
180 x 300 |
| Thermal values |
|
| -Delta-T, between 500°C and 2200°C (K) according to DIN 17052 |
± 10 |
| Max. heat-up rate (K/min) |
10 |
| Cooling time (h) |
5 |
| Connecting values |
|
| Putere (kW) |
90 |
| Voltage (V) |
400 (3P) |
| Current (A) |
3 x 130 |
| Series fuse (A) |
3 x 160 |
| Vacuum (option) |
|
| Leakage rate - clean, cold and empty (mbar l/s) |
< 5x10-3 |
| Vacuum range depending on the pumping unit |
rough, fine, high or ultra high vacuum |
| Cooling water required |
|
| Flow (l/min) |
75 |
| Max. inlet temperature (°C) |
23 |
| Gas supply |
|
| Nitrogen or Argon flow, others on request (l/h) |
50-500 |
| Controller |
|
| Manual operation |
TP1200 touch panel |
| Automatic operation |
TP1900 touch panel, Siemens S7-1500 PLC |
Supus modificărilor şi erorilor tehnice