| Dimensions: External H x W x D (mm) |
3000 x 1400 x 1400 |
| Usable space | |
| Volume (l) | 7.5 |
| Ø x H (mm) | 180 x 300 |
| Thermal values | |
| Tmax vacuum (°C) | 1050 |
| -Delta-T (K) according to DIN 17052 | ± 3 * |
| Cooling time (min) | 30 |
| Thermocouple type | K |
| Connecting values | |
| Power (kW) | 15 |
| Voltage (V) | 400 (3P) |
| Current (A) | 3 x 30 |
| Series fuse (A) | 3 x 35 |
| Controller | |
| Manual operation | Eurotherm with KP 300 panel |
| Automatic operation | Siemens |
| Cooling water required | |
| Flow (l/min) | 30 |
| Dimensions: External H x W x D (mm) |
2850 x 2100 x 1850 |
| Usable space | |
| Volume (l) | 28 |
| Ø x H (mm) | 300 x 400 |
| Thermal values | |
| Tmax vacuum (°C) | 1050 |
| -Delta-T (K) according to DIN 17052 | ± 3 * |
| Cooling time (min) | 30 |
| Thermocouple type | K |
| Connecting values | |
| Power (kW) | 30 |
| Voltage (V) | 400 (3P) |
| Current (A) | 3 x 30 |
| Series fuse (A) | 3 x 35 |
| Controller | |
| Manual operation | Eurotherm with KP 300 panel |
| Automatic operation | Siemens |
| Cooling water required | |
| Flow (l/min) | 30 |
| Dimensions: External H x W x D (mm) |
3400 x 2200 x 1400 |
| Usable space | |
| Volume (l) | 95 |
| Ø x H (mm) | 450 x 600 |
| Thermal values | |
| Tmax vacuum (°C) | 1050 |
| -Delta-T (K) according to DIN 17052 | ± 3 * |
| Cooling time (min) | 30 |
| Thermocouple type | K |
| Connecting values | |
| Power (kW) | 60 |
| Voltage (V) | 400 (3P) |
| Current (A) | 3 x 110 |
| Series fuse (A) | 3 x 150 |
| Controller | |
| Manual operation | Eurotherm with KP 300 panel |
| Automatic operation | Siemens |
| Cooling water required | |
| Flow (l/min) | 30 |
| Dimensions: External H x W x D (mm) |
4200 x 2200 x 1850 |
| Usable space | |
| Volume (l) | 170 |
| Ø x H (mm) | 450-1100 |
| Thermal values | |
| Tmax vacuum (°C) | 1050 |
| -Delta-T (K) according to DIN 17052 | ± 3 * |
| Cooling time (min) | 30 |
| Thermocouple type | K |
| Connecting values | |
| Power (kW) | 100 |
| Voltage (V) | 400 (3P) |
| Current (A) | 3 x 110 |
| Series fuse (A) | 3 x 150 |
| Controller | |
| Manual operation | Eurotherm with KP 300 panel |
| Automatic operation | Siemens |
| Cooling water required | |
| Flow (l/min) | 30 |
Please note
* at a height of 300 mm with a three zone furnace
Content may be subject to modifications or corrections