Industrial top loading furnaces


 

Industrial top loading retort furnace


  • For controlled heat treatment of hot-end components for aviation, marine and industrial engines
  • Furnace used for diffusing protective aluminium manganese chromium coatings onto turbine blades and vanes
  • Typical heat treatment cycle ranges from 2-50 hours at 1000°C
  • Furnace is rated to heat a maximum charge of 50kg to 1150°C in three hours
  • Temperature uniformity at 1150°C meets Rolls Royce RPS 953 standards
  • 300 components processed at any one time
  • Heat treatment takes place inside an inconel retort measuring 600mm internal diameter x 1750mm high
  • Argon gas creates an inert atmosphere and reduces cooling times
  • Maximum power 60kW